Altus 60 RTS
RTS motor for multiple applications
Product features
• Fixed top and bottom limit position.
• No automatic limit adjustment.
• Recommended RTS controls:
– Soliris Sensor RTS (awnings).
– Wireless timer Chronis Comfort RTS with/ without light sensor (roller shutters).
– Autonomous sun sensor Sunis WireFree sensor RTS (awnings & roller shutters).
– Wireless wind safeguard Eolis 3D WireFree sensor RTS (awnings).
– Wireless sun sensor Sunis Indoor WireFree RTS.
– Wireless sun and temperature sensor Thermosunis WireFree RTS.
• Complete series of tubular motors, series 50 and 60: 6 Nm to 120 Nm.
• Quick installation through unique clip system.
Product benefits
• Quick and easy, adjustment and operation with wireless RTS controls, e.g. Telis remote control.
• Feedback with programme actions (through movement of the end product).
• Flexible and multifunctional system: easily add, move and remove wireless RTS controls.
• Tubular motor 230 V/ 50 Hz, with built-in receiver.
• Reception range: 20 metres through 2 concrete walls.
• Easy commissioning wirelessly using the remote control.
• Adjustable intermediate position is possible.
• 1 Altus RTS tubular motor can be controlled wirelessly from a maximum 12 wireless controls and 3 RTS sensors.
• Not applicable with relay boxes, standard switches and standard controls.
• Not suitable for continuous use and with the ABS systems.
• Limit switch capacity 250 revolutions (Altus 50 RTS) and 200 revolutions
(Altus 60 RTS).
• Series Altus 50 fits in a tube with a minimum inner diameter of 47 mm, with the Altus 60 it is 60 mm.
• Supplied as standard with a white 3-core (VVF) cable. length 3 m. Axial and radial cable outlet.
Altus 60 RTS motors with standard rpm (12 or 17 rev/ min)
Type of motor | Torque (Nm) | RPM (rev/ min.) | Tensile strength with tube (kg - ø mm) | Reference number |
---|---|---|---|---|
Altus 55/ 17 RTS | 55 | 17 | 24 - ø 50 | 1 161 114 |
Altus 70/ 17 RTS | 70 | 17 | 40 - ø 50 | 1 163 101 |
Altus 85/ 17 RTS | 85 | 17 | 60 - ø 50 | 1 165 099 |
Altus 100/ 12 RTS | 100 | 12 | 80 - ø 50 | 1 166 060 |
Main technical data:
Altus RTS 55/ 17 | Altus RTS 70/ 17 | Altus RTS 85/ 17 | Altus RTS 100/ 12 | Altus RTS 120/ 12 | |
---|---|---|---|---|---|
X = motor length (mm) | 734 | 734 | 734 | 734 | 734 |
Y = drill distance (mm) | 717 | 717 | 717 | 717 | 717 |
Torque (Nm) | 55 | 70 | 85 | 100 | 120 |
RPM (rev/ min.) | 17 | 17 | 17 | 12 | 12 |
Tensile strength of tube ø 63 mm (kg) | 175 | 222 | 270 | 317 | 381 |
Limit capacity (rev.) | 200 | 200 | 200 | 200 | 200 |
Tolerance | <±3° | <±3° | <±3° | <±3° | <±3° |
Power (Watt) | 320 | 410 | 450 | 410 | 450 |
Voltage (Volt) | 230 | 230 | 230 | 230 | 230 |
Current (Ampere) | 1.5 | 1.9 | 2.1 | 1.9 | 2.1 |
Maximum run time (min.) | 4 | 4 | 4 | 4 | 4 |
Maximum motor temperature (°C) | 150 | 150 | 150 | 150 | 150 |
Minimum tube diameter (mm) | 63 x 1.5 | 63 x 1.5 | 63 x 1.5 | 63 x 1.5 | 63 x 1.5 |
Weight (kg) | 4.39 | 4.82 | 5.03 | 4.82 | 4.91 |
Length of the cable (m) | 3 | 3 | 3 | 3 | 3 |
Number of cores | 3 | 3 | 3 | 3 | 3 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C)) | -10/+40 | -10/+40 | -10/+40 | -10/+40 | -10/+40 |