Altus 50 RTS
RTS motor for multiple applications
Product features
• Fixed top and bottom limit position.
• No automatic limit adjustment.
• Recommended RTS controls:
– Soliris Sensor RTS (awnings).
– Wireless timer Chronis Comfort RTS with/ without light sensor (roller shutters).
– Autonomous sun sensor Sunis WireFree sensor RTS (awnings & roller shutters).
– Wireless wind safeguard Eolis 3D WireFree sensor RTS (awnings).
– Wireless sun sensor Sunis Indoor WireFree RTS.
– Wireless sun and temperature sensor Thermosunis WireFree RTS.
• Complete series of tubular motors, series 50 and 60: 6 Nm to 120 Nm.
• Quick installation through unique clip system.
Product benefits
• Quick and easy, adjustment and operation with wireless RTS controls, e.g. Telis remote control.
• Feedback with programme actions (through movement of the end product).
• Flexible and multifunctional system: easily add, move and remove wireless RTS controls.
• Tubular motor 230 V/ 50 Hz, with built-in receiver.
• Reception range: 20 metres through 2 concrete walls.
• Easy commissioning wirelessly using the remote control.
• Adjustable intermediate position is possible.
• 1 Altus RTS tubular motor can be controlled wirelessly from a maximum 12 wireless controls and 3 RTS sensors.
• Not applicable with relay boxes, standard switches and standard controls.
• Not suitable for continuous use and with the ABS systems.
• Limit switch capacity 250 revolutions (Altus 50 RTS) and 200 revolutions
(Altus 60 RTS).
• Series Altus 50 fits in a tube with a minimum inner diameter of 47 mm, with the Altus 60 it is 60 mm.
• Supplied as standard with a white 3-core (VVF) cable. length 3 m. Axial and radial cable outlet.
Altus 50 RTS motors with standard rpm (12 or 17 rev/ min)
Type of motor | Torque (Nm) | RPM (rev/ min.) | Tensile strength with tube (kg - ø mm) | Reference number |
---|---|---|---|---|
Altus 6/ 17 RTS | 6 | 17 | 24 - ø 50 | 1 032 444 |
Altus 10/ 17 RTS | 10 | 17 | 40 - ø 50 | 1 037 397 |
Altus 15/ 17 RTS | 15 | 17 | 60 - ø 50 | 1 039 375 |
Altus 20/ 17 RTS | 20 | 17 | 80 - ø 50 | 1 041 386 |
Altus 25/ 17 RTS | 25 | 17 | 100 - ø 50 | 1 043 168 |
Altus 30/ 17 RTS | 30 | 17 | 120 - ø 50 | 1 045 340 |
Altus 35/ 17 RTS | 35 | 17 | 140 - ø 50 | 1 047 223 |
Altus 40/ 17 RTS | 40 | 17 | 160 - ø 50 | 1 049 443 |
Main technical data:
Altus RTS 6/ 17 | Altus RTS 10/ 17 | Altus RTS 15/ 17 | Altus RTS 20/ 17 | |
---|---|---|---|---|
X = motor length (mm) | 605 | 655 | 655 | 655 |
Y = drill distance (mm) | 590 | 640 | 640 | 640 |
Torque (Nm) | 6 | 10 | 15 | 20 |
RPM (rev/ min.) | 17 | 17 | 17 | 17 |
Tensile strength of tube ø 50 mm (kg) | 24 | 40 | 60 | 80 |
Limit capacity (rev.) | 250 | 250 | 250 | 250 |
Tolerance | <±3° | <±3° | <±3° | <±3° |
Power (Watt) | 90 | 120 | 140 | 160 |
Voltage (Volt) | 230 | 230 | 230 | 230 |
Current (Ampere) | 0.45 | 0.5 | 0.65 | 0.75 |
Maximum run time (min.) | 4 | 4 | 4 | 4 |
Maximum motor temperature (°C) | 140 | 140 | 150 | 150 |
Minimum tube diameter (mm) | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 |
Weight (kg) | 1.72 | 1.85 | 1.95 | 2.15 |
Length of the cable (m) | 3 | 3 | 3 | 3 |
Number of cores | 3 | 3 | 3 | 3 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C)) | -10/+40 | -10/+40 | -10/+40 | -10/+40 |
Altus RTS 25/ 17 | Altus RTS 30/ 17 | Altus RTS 6/ 32 | Altus RTS 10/ 32 | |
---|---|---|---|---|
X = motor length (mm) | 655 | 675 | 655 | 655 |
Y = drill distance (mm) | 640 | 660 | 640 | 640 |
Torque (Nm) | 25 | 30 | 6 | 10 |
RPM (rev/ min.) | 17 | 17 | 32 | 32 |
Tensile strength of tube ø 50 mm (kg) | 100 | 120 | 24 | 40 |
Limit capacity (rev.) | 250 | 250 | 250 | 250 |
Tolerance | <±3° | <±3° | <±3° | <±3° |
Power (Watt) | 170 | 240 | 120 | 160 |
Voltage (Volt) | 230 | 230 | 230 | 230 |
Current (Ampere) | 0.8 | 1.1 | 0.5 | 0.75 |
Maximum run time (min.) | 4 | 4 | 4 | 4 |
Maximum motor temperature (°C) | 150 | 150 | 140 | 150 |
Minimum tube diameter (mm) | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 |
Weight (kg) | 2.2 | 2.55 | 2.2 | 2.2 |
Length of the cable (m) | 3 | 3 | 3 | 3 |
Number of cores | 3 | 3 | 3 | 3 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C)) | -10/+40 | -10/+40 | -10/+40 | -10/+40 |
Altus RTS 35/ 17 | Altus RTS 40/ 17 | Altus RTS 50/ 11 | |
---|---|---|---|
X = motor length (mm) | 675 | 745 | 675 |
Y = drill distance (mm) | 660 | 730 | 660 |
Torque (Nm) | 35 | 40 | 50 |
RPM (rev/ min.) | 17 | 17 | 12 |
Tensile strength of tube ø 50 mm (kg) | 140 | 160 | 200 |
Limit capacity (rev.) | 250 | 250 | 250 |
Tolerance | <±3° | <±3° | <±3° |
Power (Watt) | 240 | 270 | 270 |
Voltage (Volt) | 230 | 230 | 230 |
Current (Ampere) | 1.1 | 1.2 | 1.1 |
Maximum run time (min.) | 4 | 4 | 4 |
Maximum motor temperature (°C) | 150 | 140 | 150 |
Minimum tube diameter (mm) | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 |
Weight (kg) | 2.55 | 2.8 | 2.75 |
Length of the cable (m) | 3 | 3 | 3 |
Number of cores | 3 | 3 | 3 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C)) | -10/+40 | -10/+40 | -10/+40 |