Altus 40 RTS
RTS motor for blinds and screens
Product features
• Fixed top and bottom limit position.
• No automatic limit adjustment.
• Recommended RTS controls:
– ’Wireless’ Sun and wind system Soliris Sensor RTS (awning).
– Wireless timer Chronis Comfort RTS with/ without light sensor (roller shutters).
– Autonomous sun sensor Sunis WireFree sensor RTS (awning & roller shutters).
– Wireless sun sensor Sunis Indoor WireFree RTS.
– Wireless sun and temperature sensor Thermosunis WireFree RTS.
• Complete series of tubular motors, series 40: 3 Nm to 13 Nm.
Product benefits
• Quick and easy adjustment and operation with wireless RTS controls, e.g. Telis remote control.
• Feedback with programme actions (through movement of the end product).
• Flexible and multifunctional system: easily add, move and remove wireless RTS controls.
• Simplified wiring between products.
• 230 V/ 50 Hz tubular motor, with built-in receiver.
• Reception range: 20 metres through 2 concrete walls.
• Easy to programme wirelessly using a remote control.
• Adjustable intermediate position.
• 1 Altus RTS tubular motor can be controlled wirelessly from a maximum 12
wireless controls and a maximum of 3 RTS sensors.
• Not applicable with relay boxes, standard switches and standard controls.
• Altus 40 fits in a tube with a minimum inner diameter of 37 mm.
• Capacity of the final adjustment 500 revolutions.
• Supplied as standard with a white 2-core (VVF) cable. length 3 m. Axial and radial cable outlet.
• Double insulated to class II – no earth wire required.
Altus 40 RTS
Type of motor | Torque (Nm) | RPM (rev/ min.) | Tensile strength with tube (kg - ø mm) | Reference number |
---|---|---|---|---|
Altus 3/ 30 RTS | 3 | 30 | 15 - ø 40 | 1 020 056 |
Altus 4/ 14 RTS | 4 | 14 | 20 - ø 40 | 1 021 144 |
Altus 9/ 14 RTS | 9 | 14 | 45 - ø 40 | 1 023 117 |
Altus 13/ 8 RTS | 13 | 8 | 65 - ø 40 | 1 024 074 |
Main technical data:
Altus 40 RTS 3/ 30 | Altus 40 RTS 4/ 14 | Altus 40 RTS 9/ 14 | Altus 40 RTS 13/ 8 | |
---|---|---|---|---|
X = motor length (mm) | 497 | 457 | 497 | 497 |
Y = drill distance (mm) | 473 | 433 | 473 | 473 |
Torque (Nm) | 3 | 4 | 9 | 13 |
RPM (rev/ min.) | 30 | 14 | 14 | 8 |
Tensile strength of tube ø 40 mm (kg) | 15 | 20 | 45 | 65 |
Limit capacity (rev.) | 500 | 500 | 500 | 500 |
Tolerance | <±3° | <±3° | <±3° | <±3° |
Power (Watt) | 80 | 65 | 100 | 95 |
Voltage (Volt) | 230 | 230 | 230 | 230 |
Current (Ampere) | 0.4 | 0.35 | 0.5 | 0.5 |
Maximum run time (min.) | 4 | 4 | 4 | 4 |
Maximum motor temperature (°C) | 140 | 140 | 140 | 140 |
Minimum tube diameter (mm) | 40 x 1.5 | 40 x 1.5 | 40 x 1.5 | 40 x 1.5 |
Weight (kg) | 1.08 | 1.01 | 1.18 | 1.21 |
Length of the cable (m) | 3 | 3 | 3 | 3 |
Number of cores | 2 | 2 | 2 | 2 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C)) | -10/+40 | -10/+40 | -10/+40 | -10/+40 |