LT 50 HiPro

LT 50 HiPro

LT 50 HiPro diag\

Product benefits

• Simple setting using the limit buttons.
• Great accuracy of the limit setting.
• Six installation options for the motor head.
• Universal accessories for the HiPro motor range.
• Integrated plug with axial and radial cable outlet.
• Simplified installation.
• Low noise level.
• CEBEC-mark of approval
• Tubular motor 230 V/ 50Hz.
• The LT 50 fits in a tube with a minimum inner diameter of 47 mm. The LT 60 is 60 mm.
• Capacity of the LT 50: 46 revolutions. LT 60: 35 revolutions.
• Supplied as standard with a white 4-core (VVF) cable. 2.5 m long.
• Compatible with all Somfy controls.

LT 50 HiPro motors with standard rpm (12 or 17 rev/ min)

Type of
motor
Torque (Nm)RPM
(rev/ min.)
Tensile strength
with tube
(kg - ø mm)
Reference
number
Ariane 6/ 1761724 - ø 501 032 052
Jet 10/ 12101240 - ø 501 037 054
Atlas 15/ 12151260 - ø 501 039 044
Meteor 20/ 12201280 - ø 501 040 145
Gemini 25/ 172517100 - ø 501 043 043
Helios 30/ 123012120 - ø 501 045 037
Apollo 35/ 173517140 - ø 501 047 032
Mariner 40/ 124012160 - ø 501 049 054
Vectran 50/ 125012200 - ø 501 051 031

Main technical data:

 ArianeJetAtlasMeteorGeminiHelios
X = motor
length (mm)
505525555555605605
Y = drill
distance (mm)
490510510540540590
Torque (Nm)61015202530
RPM (rev/ min.)171717171717
Tensile strength
of tube
ø 50 mm (kg)
24406080100120
Limit switch
capacity (rev.)
464646464646
Tolerance<±5°<±5°<±5°<±5°<±5°<±5°
Power (Watt)90120140160170240
Voltage (Volt)230230230230230230
Current (Ampere)0.40.50.650.750.81.1
Maximum
run time (min.)
444444
Maximum motor
temperature (°C)
140150150150150150
Minimum tube
diameter (mm)
50 x 1.550 x 1.550 x 1.550 x 1.550 x 1.550 x 1.5
Weight (kg)1.721.851.952.152.202.55
Length of
the cable (m)
333333
Number of
cores
444444
Diameter of
the cores (mm2)
0.750.750.750.750.750.75
Protection classIP 44IP 44IP 44IP 44IP 44IP 44

 ApolloMarinerVectranAriane 6/ 32Jet 10/ 32Atlas 15/ 32
X = motor
length (mm)
605655605525555605
Y = drill
distance (mm)
590640590510540590
Torque (Nm)35405061015
RPM (rev/ min.)171712323232
Tensile strength
of tube
ø 50 mm (kg)
140160200244060
Limit switch
capacity (rev.)
464646464646
Tolerance<±5°<±5°<±5°<±5°<±5°<±5°
Power (Watt)240240240120160210
Voltage (Volt)230230230230230230
Current (Ampere)1.11.11.10.50.751.1
Maximum run
time (min.)
444444
Maximum motor
temperature (°C)
150150150140140150
Minimum tube
diameter (mm)
50 x 1.550 x 1.550 x 1.550 x 1.550 x 1.550 x 1.5
Weight (kg)2.552.552.551.852.152.55
Length of
the cable (m)
333333
Number of cores444444
Diameter of
the cores (mm2)
0.750.750.750.750.750.75
Protection classIP 44IP 44IP 44IP 44IP 44IP 44

Leave a Reply