Oximo 50 WT
Wired motor for all types of roller shutters.
Product features
• Intelligent obstacle detection in both the up and down directions.
• Motor stops if the shutter is frozen up.
• Automatic maintenance cycle – the roller shutter always opens and closes perfectly.
• Compatible with all Somfy controls.
• Torque values from 6 Nm to 40 Nm.
• Quick installation through unique clip system.
• Parallel connection of motors is possible.
Product benefits
• Setting via the WT-setting cable or WT Setting Tool.
• Feedback with programme actions (through movement of the end product).
• No access to the motor head to set the limit positions.
• Tubular motor 230 V/ 50Hz.
• Limit setting possible without access to the motor head.
• Option to combine with timer.
• Compatible with all Somfy controls.
• Fits in a tube with a minimum inner diameter of 47 mm.
• Limit switch capacity 200 revolutions.
• Supplied as standard with a white 4-core (VVF) cable. length 3 m. Axial and radial cable outlet.
• Not suitable for continuous use.
Oximo 50 WT motors with standard rpm (17 rev/ min)
Type of motor | Torque (Nm) | RPM (rev/ min.) | Tensile strength with tube (kg - ø mm) | Reference number left version |
---|---|---|---|---|
Oximo 6/ 17 WT | 6 | 17 | 24 - ø 50 | 1 032 578 |
Oximo 10/ 17 WT | 10 | 17 | 40 - ø 50 | 1 037 582 |
Oximo 15/ 17 WT | 15 | 17 | 60 - ø 50 | 1 039 493 |
Oximo 20/ 17 WT | 20 | 17 | 80 - ø 50 | 1 041 529 |
Oximo 30/ 17 WT | 30 | 17 | 120 - ø 50 | 1 045 450 |
Oximo 40/ 17 WT | 40 | 17 | 160 - ø 50 | 1 049 542 |
Main technical data:
Oximo WT 6/ 17 | Oximo WT 10/ 17 | Oximo WT 15/ 17 | Oximo WT 20/ 17 | Oximo WT 30/ 17 | Oximo WT 40/ 17 | |
---|---|---|---|---|---|---|
X = motor length (mm) | 605 | 655 | 655 | 655 | 675 | 745 |
Y = drill distance (mm) | 590 | 640 | 640 | 640 | 660 | 730 |
Torque (Nm) | 6 | 10 | 15 | 20 | 30 | 40 |
RPM (rev/ min.) | 17 | 17 | 17 | 17 | 17 | 17 |
Tensile strength of tube ø 50 mm (kg) | 24 | 40 | 60 | 80 | 120 | 160 |
Limit switch capacity (rev.) | 250 | 250 | 250 | 250 | 250 | 250 |
Tolerance | <±3° | <±3° | <±3° | <±3° | <±3° | <±3° |
Power (Watt) | 90 | 120 | 140 | 160 | 240 | 270 |
Voltage (Volt) | 230 | 230 | 230 | 230 | 230 | 230 |
Current (Ampere) | 0.45 | 0.5 | 0.65 | 0.75 | 1.1 | 1.2 |
Maximum run time (min.) | 4 | 4 | 4 | 4 | 4 | 4 |
Maximum motor temperature (°C) | 140 | 140 | 150 | 150 | 150 | 140 |
Minimum tube diameter (mm) | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 | 50 x 1.5 |
Weight (kg) | 1.72 | 1.85 | 1.95 | 2.15 | 2.55 | 2.8 |
Length of the cable (m) | 3 | 3 | 3 | 3 | 3 | 3 |
Number of cores | 4 | 4 | 4 | 4 | 4 | 4 |
Diameter of the cores (mm2) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Protection class | IP 44 | IP 44 | IP 44 | IP 44 | IP 44 | IP 44 |
Minimum/ maximum environment temperature (°C) | -10/+40 | -10/+40 | -10/+40 | -10/+40 | -10/+40 | -10/+40 |