LS40

LS 40

LS 40 diag

Product benefits

• Tubular motor 230 V/50Hz.
• Fits in a tube with a minimum inner diameter of 37 mm.
• Double insulated according to class II (no earth wire required).
• Limit switch capacity: 40 revolutions.
• Supplied as standard with a white 3-core (VVF) cable. 2.5 m long.
• Round motor head.
• Axial and radial cable outlet.
• Not suitable for continuous use.

LS 40 motors with 2.5 metre white VVF cable

Type of
motor
Torque (Nm)RPM
(rev/ min.)
Tensile strength
with tube
(kg - ø mm)
Reference
number
Mercure 3/ 3033015 - ø 401 020 010
Aries S* 4/ 1441420 - ø 401 021 041
Aries 4/ 1441420 - ø 401 021 021
Mars 9/ 1491445 - ø 401 023 010
Vulcan 13/ 813865 - ø 401 024 010

*The Aries S is c. 4.5 cm shorter than the standard Aries.

Main technical data:

 MercureAries SAriesMarsVulcan
X = motor length (mm)442398442442453
Y = drill distance (mm)421377421421433
Torque (Nm)344913
RPM (rev/ min.)301414148
Tensile strength of tube ø 40 mm (kg)1520204565
Limit switch capacity (rev.)4040404040
Tolerance±15°±15°±15°±15°±15°
Power (Watt)806565100100
Voltage (Volt)230230230230230
Current (Ampere)0.40.350.350.50.5
Maximum run time (min.)44444
Maximum motor temperature (°C)140140140140140
Minimum tube diameter (mm)40 x 1.540 x 1.540 x 1.540 x 1.540 x 1.5
Weight (kg)0.950.940.881.061.07
Length of white (WF) cable (m)2.52.52.52.52.5
Length of black (RRF) cable (m)--0.30.30.3
Number of cores33333
Diameter of the cores (mm2)0.750.750.750.750.75
Protection classIP 44IP 44IP 44IP 44IP 44