Altus 50 RTS

Altus 50 RTS

Altus 50 RTS
Altus 50 RTS diag
RTS motor for multiple applications

Product features

• Fixed top and bottom limit position.
• No automatic limit adjustment.
• Recommended RTS controls:
– Soliris Sensor RTS (awnings).
– Wireless timer Chronis Comfort RTS with/ without light sensor (roller shutters).
– Autonomous sun sensor Sunis WireFree sensor RTS (awnings & roller shutters).
– Wireless wind safeguard Eolis 3D WireFree sensor RTS (awnings).
– Wireless sun sensor Sunis Indoor WireFree RTS.
– Wireless sun and temperature sensor Thermosunis WireFree RTS.
• Complete series of tubular motors, series 50 and 60: 6 Nm to 120 Nm.
• Quick installation through unique clip system.

Product benefits

• Quick and easy, adjustment and operation with wireless RTS controls, e.g. Telis remote control.
• Feedback with programme actions (through movement of the end product).
• Flexible and multifunctional system: easily add, move and remove wireless RTS controls.
• Tubular motor 230 V/ 50 Hz, with built-in receiver.
• Reception range: 20 metres through 2 concrete walls.
• Easy commissioning wirelessly using the remote control.
• Adjustable intermediate position is possible.
• 1 Altus RTS tubular motor can be controlled wirelessly from a maximum 12 wireless controls and 3 RTS sensors.
• Not applicable with relay boxes, standard switches and standard controls.
• Not suitable for continuous use and with the ABS systems.
• Limit switch capacity 250 revolutions (Altus 50 RTS) and 200 revolutions
(Altus 60 RTS).
• Series Altus 50 fits in a tube with a minimum inner diameter of 47 mm, with the Altus 60 it is 60 mm.
• Supplied as standard with a white 3-core (VVF) cable. length 3 m. Axial and radial cable outlet.

Altus 50 RTS motors with standard rpm (12 or 17 rev/ min)

Type of
motor
Torque (Nm)RPM
(rev/ min.)
Tensile strength
with tube
(kg - ø mm)
Reference
number
Altus 6/ 17 RTS61724 - ø 501 032 444
Altus 10/ 17 RTS101740 - ø 501 037 397
Altus 15/ 17 RTS151760 - ø 501 039 375
Altus 20/ 17 RTS201780 - ø 501 041 386
Altus 25/ 17 RTS2517100 - ø 501 043 168
Altus 30/ 17 RTS3017120 - ø 501 045 340
Altus 35/ 17 RTS3517140 - ø 501 047 223
Altus 40/ 17 RTS4017160 - ø 501 049 443

Main technical data:

 Altus RTS 6/ 17Altus RTS 10/ 17Altus RTS 15/ 17Altus RTS 20/ 17
X = motor length (mm)605655655655
Y = drill distance (mm)590640640640
Torque (Nm)6101520
RPM (rev/ min.)17171717
Tensile strength of tube ø 50 mm (kg)24406080
Limit capacity (rev.)250250250250
Tolerance<±3°<±3°<±3°<±3°
Power (Watt)90120140160
Voltage (Volt)230230230230
Current (Ampere)0.450.50.650.75
Maximum run time (min.)4444
Maximum motor temperature (°C)140140150150
Minimum tube diameter (mm)50 x 1.550 x 1.550 x 1.550 x 1.5
Weight (kg)1.721.851.952.15
Length of the cable (m)3333
Number of cores3333
Diameter of the cores (mm2)0.750.750.750.75
Protection classIP 44IP 44IP 44IP 44
Minimum/ maximum environment temperature
(°C))
-10/+40-10/+40-10/+40-10/+40

 Altus RTS 25/ 17Altus RTS 30/ 17Altus RTS 6/ 32Altus RTS 10/ 32
X = motor length (mm)655675655655
Y = drill distance (mm)640660640640
Torque (Nm)2530610
RPM (rev/ min.)17173232
Tensile strength of tube ø 50 mm (kg)1001202440
Limit capacity (rev.)250250250250
Tolerance<±3°<±3°<±3°<±3°
Power (Watt)170240120160
Voltage (Volt)230230230230
Current (Ampere)0.81.10.50.75
Maximum run time (min.)4444
Maximum motor temperature (°C)150150140150
Minimum tube diameter (mm)50 x 1.550 x 1.550 x 1.550 x 1.5
Weight (kg)2.22.552.22.2
Length of the cable (m)3333
Number of cores3333
Diameter of the cores (mm2)0.750.750.750.75
Protection classIP 44IP 44IP 44IP 44
Minimum/ maximum environment temperature
(°C))
-10/+40-10/+40-10/+40-10/+40

 Altus RTS 35/ 17Altus RTS 40/ 17Altus RTS 50/ 11
X = motor length (mm)675745675
Y = drill distance (mm)660730660
Torque (Nm)354050
RPM (rev/ min.)171712
Tensile strength of tube ø 50 mm (kg)140160200
Limit capacity (rev.)250250250
Tolerance<±3°<±3°<±3°
Power (Watt)240270270
Voltage (Volt)230230230
Current (Ampere)1.11.21.1
Maximum run time (min.)444
Maximum motor temperature (°C)150140150
Minimum tube diameter (mm)50 x 1.550 x 1.550 x 1.5
Weight (kg)2.552.82.75
Length of the cable (m)333
Number of cores333
Diameter of the cores (mm2)0.750.750.75
Protection classIP 44IP 44IP 44
Minimum/ maximum environment temperature
(°C))
-10/+40-10/+40-10/+40